Scheme Information Sheets
UK NEQAS for ACE
Scheme Particulars | Indicative Details |
---|---|
Accreditation body | UKAS |
ISO/IEC Accreditation status | ISO/IEC 17043:2023 |
UKAS Accredited Proficiency Testing Provider No | 7860 |
Objective of Scheme | Provides EQA coverage for Angiotensin Converting Enzyme (ACE). ACE testing is performed in the investigation of Sarcoidosis. The scheme provides both endogenous and manipulated specimens to cover both the normal and pathological concentration ranges |
Pre-, Analytical, Post- status | Analytical |
Number of distributions per year (nominal) | 11 |
Specimens per distribution | 3 |
Number of Specimens per annum | 33 |
Frequency of distribution | Monthly |
Scoring system | ABC |
Material distributed | Pooled or single donations of liquid human serum with or without exogenous added analyte |
Programme Director(s) / Organiser(s) | Rachel Marrington |
Criteria for participation | All, but overseas by courier |
Nominal sample volume (mL) | 0.4 |
Sample presentation TACs | All analytes in the same tube |
Data in Chemistry on-line Dashboard | Yes |
Analyte | Approx Range | Default Units | Target Value | B Score Limit (%) | C Score Limit (%) |
---|---|---|---|---|---|
ACE | 10 – 100 | U/L | ALTM | 20.0 | 25.0 |
Abbreviation | Expansion |
---|---|
ALTM | All Laboratory Trimmed Mean |
GLTM | Group Laboratory Trimmed Mean – which is the Method Principle Mean |
MLTM | Method Laboratory Trimmed Mean – usually a manufacturer system / analyser mean |
XALTM | An external value that may be from a Reference Method System |
OGLTM | A Method Principle Mean used as the target for all laboratories |
OMLTM | A specific Method Mean used as a target for all laboratories |
MED | Median |