Scheme Information Sheets

UK NEQAS for ACE

Scheme Particulars Indicative Details
Accreditation body UKAS
ISO/IEC Accreditation status ISO/IEC 17043:2023
UKAS Accredited Proficiency Testing Provider No 7860
Objective of Scheme Provides EQA coverage for Angiotensin Converting Enzyme (ACE). ACE testing is performed in the investigation of Sarcoidosis. The scheme provides both endogenous and manipulated specimens to cover both the normal and pathological concentration ranges
Pre-, Analytical, Post- status Analytical
Number of distributions per year (nominal) 11
Specimens per distribution 3
Number of Specimens per annum 33
Frequency of distribution Monthly
Scoring system ABC
Material distributed Pooled or single donations of liquid human serum with or without exogenous added analyte
Programme Director(s) / Organiser(s) Rachel Marrington
Criteria for participation All, but overseas by courier
Nominal sample volume (mL) 0.4
Sample presentation TACs All analytes in the same tube
Data in Chemistry on-line Dashboard Yes
Analyte Approx Range Default Units Target Value B Score Limit (%) C Score Limit (%)
ACE 10 – 100 U/L ALTM 20.0 25.0
Abbreviation Expansion
ALTM All Laboratory Trimmed Mean
GLTM Group Laboratory Trimmed Mean – which is the Method Principle Mean
MLTM Method Laboratory Trimmed Mean – usually a manufacturer system / analyser mean
XALTM An external value that may be from a Reference Method System
OGLTM A Method Principle Mean used as the target for all laboratories
OMLTM A specific Method Mean used as a target for all laboratories
MED Median

Last Updated: